Integrity™ bare metal stent (BMS) provides flexibility and conformability without compromising strength, and features continuous sinusoid technology as well as a generous size matrix for a variety of patient anatomies.
The Integrity Coronary Stent Systems are indicated for improving coronary luminal diameter in patients with symptomatic ischemic heart disease due to discrete de novo or restenotic lesions with reference vessel diameters of 2.25–4.0 mm and ≤30 mm in length using direct stenting or predilatation.
Patients in whom antiplatelet and/or anticoagulation therapy is contraindicated • Patients who are judged to have a lesion that prevents complete inflation of an angioplasty balloon or proper placement of a stent or stent delivery system
The long-term effects of stents and the risks associated with lifelong carrying of these implants are unknown. This lack of knowledge should be considered in making a risk/benefit assessment for the patient prior to implantation. • The Integrity Coronary Stent Systems are provided sterile, for one procedure only. Do not resterilize. Use by the “Use by” date noted on the package. • Only physicians who have received appropriate training should perform implantation of the stent. Use of an Integrity Coronary Stent System requires advanced coronary angioplasty technical skills. The instructions will give technical guidance, but do not obviate the need for formal training in the use of the device. • Patients allergic to cobalt alloy may suffer an allergic reaction to this implant. • Do not remove the stent from the stent delivery system; the stent cannot be removed and placed on another balloon catheter for deployment. • Do not try to straighten a kinked shaft or hypotube. Straightening a kinked metal shaft may result in breakage of the shaft. If the device is kinked, it should not be used. • Significant amounts of air in the balloon may cause uneven expansion of the stent and difficulty in deployment of the stent. Do not pre-inflate balloon prior to stent deployment. Use balloon preparation technique described within this instructional material. • The Integrity Coronary Stent Systems do not provide for distal dye injections or pressure measurements through the guidewire lumen. • Expansion of the stent should not be undertaken if the stent is not appropriately positioned in the vessel. If the position of the stent is not optimal, it should not be expanded. • Incomplete deployment of the stent (i.e., stent not fully expanded) may cause procedural complications resulting in patient injury. • Advancement of an Integrity Coronary Stent System through a previously stented segment may cause procedural complications resulting in patient injury. • Placement of the stent has the potential to compromise sidebranch patency. • Administer appropriate anticoagulant/ antiplatelet and coronary artery vasodilator therapy according to current medical guidelines and manufacturer’s instructions. • Caution must be taken when using ancillary equipment, such as intravascular ultrasound catheters, to avoid dislodgement or deformation of the stent. • When multiple stents are required, stent materials should be of similar composition. Placing multiple stents of different materials in contact with each other may increase the potential for corrosion. Data obtained from in vitro corrosion tests using a cobalt alloy stent (Medtronic Integrity Coronary Stent) in combination with a stainless steel alloy stent (Boston Scientific Liberté® Coronary Stent) do not suggest an increased risk of in vivo corrosion. • When using two wires, care should be taken when introducing, torquing and removing one or both guidewires to avoid entanglement. It is recommended that one guidewire be completely withdrawn from the patient before removing any additional equipment. • Stent placement should only be performed at hospitals where emergency coronary artery bypass graft surgery can be readily performed. • Judicious selection of patients is necessary since the use of this device carries the associated risk of subacute thrombosis, vascular complications and/or bleeding events. Administration of appropriate anticoagulant, antiplatelet and coronary vasodilator therapy is critical to successful stent implantation and follow-up. • Subsequent restenosis may require repeat dilatation of the arterial segment containing the stent. The long-term outcome following repeat dilatation of endothelialized coronary stents is unknown at present.
The following complications may be associated with the use of coronary stenting devices or PTCA:
• Acute myocardial infarction • Allergic reaction to contrast medium/stent material/medications • Arrhythmias (including ventricular fibrillation and ventricular tachycardia)
• Arteriovenous fistula • Bleeding complications
• Cardiac tamponade • Cerebrovascular accident/stroke •Death
• Dissection of coronary artery • Drug reactions
• Embolization (air, stent, tissue or thrombotic)
• Emergency coronary artery bypass graft surgery (CABG)
• Endocarditis • Failure to deliver the stent • Stent deformation, collapse or fracture
• Hematoma • Hemorrhage requiring transfusion • Injury of the coronary artery • Myocardial ischemia/infarction • Pain and tenderness at the insertion site • Perforation • Peripheral Ischemia • Peripheral nerve injury • Pseudoaneurysm (coronary/femoral/radial) • Pyrogenic reaction • Restenosis of the dilated artery or stented segment • Sepsis/infection • Short-term hemodynamic deterioration (hypotension/hypertension) • Stent thrombosis or occlusion • Total occlusion of coronary artery • Unstable angina • Vascular thrombosis • Vessel dissection/perforation/spasm Please reference appropriate product Instructions for Use for a more detailed list of indications, warnings, precautions and potential adverse events.
CAUTION:
Federal (USA) law restricts this device to sale by or on the order of a physician.
"Providing quality product with right information of latest technology to cater requirement of medical professionals."
Shristi Enterprises has been providing excellent services for last many years. The support services provided are very good and they are very prompt in dealing with any of the issues pertaining to instruments.
Shristi Enterprises is dedicated for health care services always ready to provide prompt services to the customer whenever needed . Executives and dealer are ready to help any time .
Amit Sharma
Founder
Hi, I am Amit Sharma, founder of Shristigroup. I started this organization in 2001. Since inception my vision is to make Shristi Enterprises the number one organization in medical & healthcare supplies in Chattishgarh, INDIA, After achieving the same, now I am looking to expand its operation across India.
We have a team of 50+ workforce which include people who have worked at top positions in Sales & Customer Service of reputed medical instrument manufacturer companies. We have the state of the art Infrastructure which includes 10,000 sqft warehouse in Raipur (our HQ) & satellite offices in Bhopal & Indore (M.P.) & in Mumbai. Apart from warehousing, we have our own transportation system to ensure timely & safe deliveries to all our customers.
For product sustainability, material storage and logistics is number one priority for us. We have our in-house supply chain management integrated with freight forwarding and contract logistics to provide seamless distribution process from manufacturers to our customers.
We also use latest softwares to ensure we operate at maximum efficiency. We have state of the art, third party developed accounting, employee management, inventory management & delivery tracking software.
Our satisfied customers include AIIMS Raipur, Bhilai Steel Plant, Government Medical College Raipur and various private hospitals in MP, CG and rest of INDIA.